• Please clean the unit with so coon cloth, don't use the organic impregnant or chemical clean agent.
If necessary, please use a lile pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad directly.
Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.
• Pay aenon to the high voltage inside the products, please refer service only to a trained and qualified
professional.
8. Precausons
• Power Supply : DC 24V (supplied by PS4-24V or PS5-24V)
• Power Consumon : Standby 60mA; Working status 200mA
• Camera : Pinhole Sharp Color CCD; 420 TV Lines
• Lock Power Supply : 12Vdc, 300mA(Internal Power)
• Number of relay circuits : 2
• Mounng : Surface mounng(DT596/ID), Flush mounng (DT596F/ID)
• Working temperature : -10ºC ~ +45ºC
• Wiring : 2 wires,non-polarityC
• Dimension: 176(H)×90(W)×28(D)mm(DT596/ID), 220(H)×119(W)×52(D)mm(DT596F/ID)
9. Specificaons
-15--14-
• If an authorized user card is being shown the buzzer will sound of beep+,
and the LED indicator will light up.
• If the unauthorized user card is being shown, the buzzer will sound of beep 3 mes.
Show the MASTER CARD
ADD card to ID card window
in standby mode.
beep+,beep
red
(on)
(off)
blue
Show the MASTER CARD
ADD card to exit.But it will
return to standby mode if no
operaon within 15s.
beep,beep+
red
(off)
(off)
blue
Show user cards to be
added, one by one.
beep+
red
(blink)
(off)
blue
6.2.5 Authorize master cards:
By default,there are two master cards marked MASTER CARD ADD and MASTER CARD DELETE, but you
should know that the master card can be authorized by users at any me. That means any two user cards
can be authorized to master cards, when registered new master cards, the old master cards will be invalid
automacally.
7. Unlock Operaons
When the registered user card has been shown to ID card window, the LED indicator (the first lock : red ;
the second lock : blue) lights up, the buzzer sounds, and the electric door strike will be unlocked.
Note 1 : if the user card controls one lock only,show the user card to release the first lock.red indicator lights up.
Note 2 : if the user card controls two locks,show the user card to ID card window in standby mode,the red & blue
indicator flashes for 1.5s alternately.During this me,press "CALL" buon to release the second lock.
Otherwise, release the first lock if there isn't any operaon within 1.5 seconds.
• If 10 mes unauthorized access cards are connuously aempted, the release funcon will be forbidden
and the showing card operaon will be disabled for 60 seconds.
• If the DIP3 switch is set to 1 and the relay 2 doesn't respond the second lock, in which when showing
user cards controlling two locks or when pressing unlock 2nd on monitor, the monitor, the second lock
whouldn’t release. At this point, aer to 10th aempts of showing access card, relay 2 will be closed for
60 seconds and the buzzer will connuously sound about 8 mes, if the system is connected to thr alarm,
the alarm funcon will be acvated.
7.1 Unlocking ID Card
Example: Release the first lock
Red LED lights up
(During relay 1 operaon)
beep+
red
(on)
(off)
blue
Example: Release the second lock
Red LED lights up
(During relay 2 operaon)
beep+
red
(off)
(on)
blue
• You can acvate the electric door strike by pressing the request to exit buon connected to the unit.
Pressing request to exit buon 1 releases relay 1, and pressing request to exit buon 2 releases relay
2.(The unlock funcon will work when the request to exit buon is being pushed, even while the
proximity access is forbidden.