5. DIP Switches Seng
-11--10-
4.5 Mul Monitors Connecon
5.1 DIP Switches Sengs of Door Staon
5.2 DIP Switches Sengs of Monitor
Basic IN-OUT Wiring Mode
ON(1)
=
OFF(0)
=
ON
ON
1
2
3 4
ON
1
2
3 4
ON
1
2
3 4
ON
1
2
3 4
ON
1
2
3 4
ON
1
2
3 4
ON
Total 4 bits on the DIP switches can be configured.The switches can be modified either before or aer installaon.
Seng Item Bit State Descripons
Bit1 and Bit2
(it is used to set
the ID code for
door staon)
Default seng, ID = 0(00), set to the first Door Staon.
ID = 1(10), set to the second Door Staon.
ID = 2(01), set to the third Door Staon.
ID = 3(11), set to the fourth Door Staon.
Bit3
Bit4
Acvate external output seng,the relay 2 terminal doesn't
respond to the second lock and will be closed for 60 seconds
when the "Lockout" is carried out.The alarm connected to
the terminal of relay 2 will be acvated.
inacvate
Reserve
There are 6 bit switches in total. The DIP switches are used to configure the User Code for each Monitor.
Bit-6 is line terminal switch, which needs to be set to ON if the Monitor is in the end of the bus, otherwise set to OFF.
Bit state Seng Bit state Seng
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
The monitor is
not at the end
of the bus.
The monitor is
at the end of
the bus.
Code=0, DIP-6=off
Code=14, DIP-6=off
Code=15, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
monitor
monitor
monitor
1
2
3 4
ON
ID=00
85~260AC
DPS
PS5
Aenon: You must follow the dip switch sengs in the table on page 12.
So, 1st monitor all switches down, 2nd monitor switch 1 up, 3rd monitor
switch 2 up, etc.